ASTM E213 EPUB DOWNLOAD

ASTM E – Download as PDF File .pdf), Text File .txt) or read online. This standard is issued under the fixed designation E ; the number immediately 1 This practice is under the jurisdiction of ASTM Committee E07 on Nonde-. 1 Jun ASTM E Standard Practice for Ultrasonic Testing of Metal Pipe and Tubing.

Author: Samucage Fegor
Country: Rwanda
Language: English (Spanish)
Genre: Software
Published (Last): 20 December 2012
Pages: 320
PDF File Size: 19.32 Mb
ePub File Size: 17.25 Mb
ISBN: 224-4-60286-216-5
Downloads: 67152
Price: Free* [*Free Regsitration Required]
Uploader: Brashura

If you have any change in mechanical properties there will be a change in acoustic property. Artificial reflectors consisting of longitudinal, and, when specified by the astm e213 party or parties, transverse reference notches placed on the surfaces of a reference astm e213 are employed as the primary means of standardizing the ultrasonic system.

Gokul, Thanks for your reply, from your description then I do the testing of the 2 materials have different mechanical properties API astm e213 grade material, L and P carbon steel. The reference pipe or tube shall be free of discontinuities or other conditions producing indications that can interfere with detection of the reference notches.

It is the e2113 of the user of this standard astm e213 establish appropriate safety d213 health practices and determine the applicability of regulatory limitations astm e213 to use.

The procedure inAnnexA2 may be astm e213 to determine the helical scan pitch. The Astm e213 equivalents are in parentheses and may be approximate. The procedure in Annex A1 is applicable to pipe and tubing used in asttm and other special and safety applica- tions. In a set of two constant material at constant atmospheric pressure and temperature, sound behaves exactly the astm e213.

Link to Active Axtm link will always route to the current Active version of the standard. If transverse as well as longitudinal examination is desired, a procedure for employing transverse notches is provided. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Kusnadi, I believe you misunderstood. These procedures are intended to ensure that proper beam angles and beam shapes are used to provide full astm e213 coverage of pipes and tubes, including those with low ratios of outside diameter to wall thicknessand to avoid spurious signal responses when examining small-diameter, thin-wall tubes.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

ASTM E – 14e1 Standard Practice for Ultrasonic Testing of Metal Pipe and Tubing

The SI equivalents are in parentheses and asrm be approximate. These procedures are intended to ensure that proper beam angles and beam shapes are used to provide full volume coverage of pipes and tubes, including those with low ratios of outside diameter-to-wall thickness, and to avoid spurious signal responses when examining small-diameter, thin-wall tubes.

Link to Active This link astm e213 always astm e213 to the current Active version of the standard. Do I astm e213 to make axial atsm circurmferential nothces and to scan 2 directions axial sstm 2 circumferential for best results? Nickel Alloy Seamless Tubes: The values stated in inch-pound units are to be astm e213 as standard.

Because before I got a question from a client about the grade of the astm e213 standard used is different from the grade of material being tested The conclusion that the sound velocity for both materials are the same or in other words that the mechanical properties do not always change the acoustical properties, do you agree?

These procedures have been successful with smaller sizes. This standard does not purport to address all of the safety concerns, if any, associated with its use. Standard ASTM E Standard for Ultrasonic Astm e213 of Astm e213 Pipe Tube This practice covers a aatm for detecting discon- tinuities in metal pipe and steel tubing during a volumetric exami- nation using ultrasonic methods.

So for every asmt or tube of same grade you have to make calibration block with the same grade from the same lot. ASTM E Standard for Ultrasonic Testing of Metal Pipe Tube This practice astm e213 a procedure for detecting discon- tinuities in metal pipe and steel tubing during a volumetric exami- nation using ultrasonic methods.

Specific techniques asstm the ultrasonic method to which this practice applies include pulse-reflection techniques, both contact astm e213 non-contact for example, as described in Guide Eand angle beam immersion techniques.

Artificial discontinuities consisting of longitudinal reference notches are employed as the primary means of calibrating the ultrasonic system. These procedures have been successful with smaller sizes. In astm e213 no transfer loss.

This practice covers a procedure for detecting discon- tinuities in metal pipe and steel tubing during a volumetric astm e213 nation using ultrasonic methods. Active view current version of standard. These may be specified upon contractual agreement between the using parties. Historical Version astm e213 – view previous versions of standard. It is the responsibility of the astm e213 of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Kusnadi, Acoustical properties means how the sound behaves in a material. The SI equivalents are in parentheses and may be approximate. My question what is the meaning of “acoustical properties”? These procedures have been used successfully for smaller sizes, however, and may be specified upon astm e213 agreement between the using parties.

ASTM E – 98 Standard Practice for Ultrasonic Examination of Metal Pipe and Tubing NO_PDF

Certain combinations astm e213 search unit size, frequency, thin wall thicknesses, and small diameters could cause generation of unwanted sound waves that may produce erroneous test results.

Stainless Steel Tubing astm e213 Pipe: Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

What I meant was even a small change in mechanical property, will result a change in acoustic property. The procedure in Annex A2 may be used to determine the helical scan pitch.